secstester_getsvidvalue

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
secstester_getsvidvalue [2020/05/12 19:26]
wikiadmin
secstester_getsvidvalue [2020/05/12 19:29] (current)
wikiadmin
Line 3: Line 3:
   - Start the SECS Tester   - Start the SECS Tester
   - Double-Click on "Set Up Communications to Tool" to open the Communications Setup Dialog   - Double-Click on "Set Up Communications to Tool" to open the Communications Setup Dialog
-   - The default tool configuration will be shown. You can change the tool name so that this configuration will be saved as a new tool setup. +       - The default tool configuration will be shown. You can change the tool name so that this configuration will be saved as a new tool setup. 
-   - Enter the HSMS Port (or SECS I Port, a port number < 255) +       - Enter the HSMS Port (or SECS I Port, a port number < 255) 
-   - Enter the Device ID +       - Enter the Device ID 
-   - Enter the new tool name +       - Enter the new tool name 
-   - Save the configuration by pressing the Save button, then the close button+       - Save the configuration by pressing the Save button, then the close button
   - Select the new tool configuration from the combo box. You should see the tool configuration printed out in the text field on the right.   - Select the new tool configuration from the combo box. You should see the tool configuration printed out in the text field on the right.
-  - Connect to the tool +   - Connect to the tool 
-   *  Press "Connect To Tool" button to send an S1F13 to the tool.  +       - Press "Connect To Tool" button to send an S1F13 to the tool.  
-   *  If the communications was successful you will see a response from the tool. +       -  If the communications was successful you will see a response from the tool. 
-   * # Go online-remote with the tool +  Go online-remote with the tool 
-   *  Be sure the tool is ready to go online with this host and is allowing remote communications.  +       - Be sure the tool is ready to go online with this host and is allowing remote communications.  
-   *  Press "Request ONLINE" button to send an S1F17 to the tool.  +       -  Press "Request ONLINE" button to send an S1F17 to the tool.  
-   *  If the online request was successful you will see an S1F18 response with a reply other than "1" (which means it cannot go online).+       - If the online request was successful you will see an S1F18 response with a reply other than "1" (which means it cannot go online).
   - Once the tool is ONLINE-REMOTE you can get a list of SVIDs and request the current value of any of them.   - Once the tool is ONLINE-REMOTE you can get a list of SVIDs and request the current value of any of them.
-   Double-Click "Check SVID Values" to launch the SVID Report dialog +       Double-Click "Check SVID Values" to launch the SVID Report dialog 
-   * Click on the "Get List of SVIDs" button to send an S1F11 to the tool +       - Click on the "Get List of SVIDs" button to send an S1F11 to the tool 
-   * If the tool has SVIDs, these VIDs will show up in the SVID List combo box, alphabetically by SVID name +       - If the tool has SVIDs, these VIDs will show up in the SVID List combo box, alphabetically by SVID name 
-   * Select an SVID and press the "Get Current Value" to send an S1F3 to the tool +       - Select an SVID and press the "Get Current Value" to send an S1F3 to the tool 
-   * The current value will be displayed below the "Get Current Value" button+       - The current value will be displayed below the "Get Current Value" button