secstester_getsvidvalue

This is an old revision of the document!


How to Get an SVID Value from the Tool

  1. Start the SECS Tester
  2. Double-Click on “Set Up Communications to Tool” to open the Communications Setup Dialog
  3. * The default tool configuration will be shown. You can change the tool name so that this configuration will be saved as a new tool setup.
  4. * Enter the HSMS Port (or SECS I Port, a port number < 255)
  5. * Enter the Device ID
  6. * Enter the new tool name
  7. * Save the configuration by pressing the Save button, then the close button
  8. * # Select the new tool configuration from the combo box. You should see the tool configuration printed out in the text field on the right.
  9. Connect to the tool
  10. * Press “Connect To Tool” button to send an S1F13 to the tool.
  11. * If the communications was successful you will see a response from the tool.
  12. * # Go online-remote with the tool
  13. * Be sure the tool is ready to go online with this host and is allowing remote communications.
  14. * Press “Request ONLINE” button to send an S1F17 to the tool.
  15. * If the online request was successful you will see an S1F18 response with a reply other than “1” (which means it cannot go online).
  16. Once the tool is ONLINE-REMOTE you can get a list of SVIDs and request the current value of any of them.
  17. * Double-Click “Check SVID Values” to launch the SVID Report dialog
  18. * Click on the “Get List of SVIDs” button to send an S1F11 to the tool
  19. * If the tool has SVIDs, these VIDs will show up in the SVID List combo box, alphabetically by SVID name
  20. * Select an SVID and press the “Get Current Value” to send an S1F3 to the tool
  21. * The current value will be displayed below the “Get Current Value” button
  • secstester_getsvidvalue.1589329498.txt.gz
  • Last modified: 2020/05/12 19:24
  • by wikiadmin